NSE6_FSW-7.2 Actual Questions Answers PDF 100% Cover Real Exam Questions [Q16-Q35]

Share

NSE6_FSW-7.2 Actual Questions Answers PDF 100% Cover Real Exam Questions

NSE6_FSW-7.2 Exam questions and answers


Fortinet NSE6_FSW-7.2 exam is an essential certification exam for IT professionals who want to validate their expertise in managing Fortinet switches. NSE6_FSW-7.2 exam covers a range of topics related to the FortiSwitch 7.2, including switch administration, VLANs, STP, LACP, FortiLink, FortiNAC, and FortiTelemetry. Successful completion of the exam demonstrates that the candidate has the skills and knowledge required to manage and maintain Fortinet switches in an enterprise environment.


Fortinet NSE6_FSW-7.2 exam is a certification that validates the skills of network professionals in configuring, managing, and troubleshooting FortiSwitch products. FortiSwitch is a line of Ethernet switches that provide secure access and connectivity for enterprises, data centers, and service providers. The NSE6_FSW-7.2 exam is designed to test the knowledge of network engineers who work with FortiSwitch products and are responsible for ensuring the security and performance of their network infrastructure.

 

NEW QUESTION # 16
Which Ethernet frame can create Layer 2 flooding due to all bytes on the destination MAC address being set to all FF?

  • A. The multicast Ethernet frame
  • B. The broadcast Ethernet frame
  • C. The unicast Ethernet frame
  • D. The anycast Ethernet frame

Answer: B


NEW QUESTION # 17
Refer to the exhibits.


Port1 and port2 are the only ports configured with the same native VLAN 10.
What are two reasons that can trigger port1 to shut down? (Choose two.)

  • A. Loop guard frame sourced from port 1 was received on port 1.
  • B. port1 was shut down by loop guard protection.
  • C. STP triggered a loop and applied loop guard protection on port1.
  • D. An endpoint sent a BPDU on port1 that it received from another interface.

Answer: C,D


NEW QUESTION # 18
Which statement about 802.1X security profiles using MAC-based authentication mode is true?

  • A. FortiSwitch must communicate with the RADIUS server to authenticate devices
  • B. FortiSwitch allows connectivity to all hosts connected to a port, if one host is authenticated.
  • C. FortiSwitch performs faster when using this security mode on the ports.
  • D. FortiSwitch can grant each device a different access level based on the credentials provided

Answer: D


NEW QUESTION # 19
How does FortiGate handle configuration of flow tracking sampling if you export the settings to a managed FortiSwitch stack with sampling mode set to perimeter is true?

  • A. FortiGate configures and enables flow sampling on FortiSwitch but does not change existing sampling settings of interfaces.
  • B. FortiGate configures FortiSwitch to perform ingress sampling on all switch interfaces.
  • C. FortiGate configures and enables egress sampling on all management interfaces.
  • D. FortiGate configures FortiSwitch to perform ingress sampling on all switch interfaces, except ICL and ISL interfaces.

Answer: D


NEW QUESTION # 20
Exhibit.

LAG and MCLAG are used to increase the available network bandwidth and enable redundancy. How does spanning tree protocol see MCLAG and LAG if they are configured based on the physi-cal view shown in the exhibit? (Choose two)

  • A. Switch 3 and switch 4 are seen as one MCLAG switch client
  • B. Switch 3 and Switch 4 uplinks are treated as single interfaces.
  • C. Switch 1 and Switch 2 both seen as one single switch.
  • D. Switch 1. Switch 2, and Switch 3 are seen as one MCLAG peer group

Answer: A,C


NEW QUESTION # 21
Refer to the exhibit.

Core-1 and Access-1 are managed and authorized by FortiGate-1. which uses port4 as the FortiLink interface. After FortiGate authorizes and manages Core-2. Port1 status becomes STP discarding.
Why is port1 in the discarding state?

  • A. Core-1 and Core-2 do not have MCLAG configuration.
  • B. port1 on Core-2 is discarding only management traffic.
  • C. Core-2 has the lowest bridge priority.
  • D. Access-1 is the root bridge and can only have one root port.

Answer: A


NEW QUESTION # 22
Which two statements about VLAN assignments on FortiSwitch ports are true? (Choose two.)

  • A. Configure a native VLAN on the FortiLink
  • B. Only assign one native VLAN on a port
  • C. Assign untagged VLANs using FortiGate CLI
  • D. Assign an IP address and subnet mask to FortiSwitch VLANs

Answer: B,C


NEW QUESTION # 23
FortiGate is unable to establish a tunnel with the FortiSwitch device it is supposed to manage Based on the debug output shown in the exhibit, what is the reason for the failure?

  • A. DTLS client hello had the incorrect pre-shared key.
  • B. The CAPWAP tunnel failed to come up due to a mismatch in time.
  • C. The handshake process timed out before FortiSwitch responded.
  • D. FortiSwitch has disabled FortiLink and is only managed as a standalone.

Answer: B


NEW QUESTION # 24
Exhibit.

Which configuration change will allow the managed FortiSwitch to accept SNMP requests from any source?

  • A. Add SNMP service on the management interface of the switch.
  • B. Enable SNMP on the internal interface of the switch.
  • C. Configure an SNMP host to send SNMP traps.
  • D. Create a new local access profile for SNMP only.

Answer: C


NEW QUESTION # 25
Which two statements about DHCP snooping enabled on a FortiSwitch VLAN are true? (Choose two.)

  • A. By default, all FortiSwitch ports are set to forward client DHCP requests to untrusted ports.
  • B. Enabling DHCP snooping on a FortiSwitch VLAN ensures requests and replies are seen by all DHCP servers.
  • C. switch-controller-dhcp-snooping-verify-mac verifies the destination MAC address to protect against DHCP exhaustion attacks.
  • D. Settings related to DHCP option 82 are only configurable through the CLI

Answer: A,D


NEW QUESTION # 26
Which two statements about the FortiLink authorization process are true? (Choose two.)

  • A. FortiSwitch requires a reboot to complete the authorization process.
  • B. FortiLink authorization sets the FortiSwitch management mode to FortiLink.
  • C. A FortiLink frame is sent by FortiGate to FortiSwitch to complete the authorization.
  • D. The administrator must manually pre-authorize FortiGate on FortiSwitch by adding the FortiGate serial number.

Answer: B,C


NEW QUESTION # 27
What can an administrator do to maintain a FortiGate-compatible FortiSwitch configuration when changing the management mode from standalone to FortiLinK?

  • A. FortiGate automatically saves the existing FortiSwitch configuration during the FortiLink management process.
  • B. Register FortiSwitch to FortiSwitch Cloud to save a copy before managing with FortiGate.
  • C. Enable the FortiLink setting on FortiSwitch before the authorization process.
  • D. Use a migration tool based on Python script to convert the configuration.

Answer: B


NEW QUESTION # 28
Exhibit.

The exhibit shows the current status of the ports on the managed FortiSwitch.
Access-1.
Why would FortiGate display a serial number in the Native VLAN column associated with the port23 entry?

  • A. A standalone switch with the showm serial number is connected on por123.
  • B. Port23 is configured as the dedicated management interface.
  • C. Ports connect to adjacent FortiSwitch devices will show their.serial number as the na-tive VLAN
  • D. Port23 is a member of a trunk that uses the Access-1 FortiSwitch senal number as the name of the trunk.

Answer: C


NEW QUESTION # 29
Which QoS mechanism maps packets with specific CoS or DSCP markings to an egress queue?

  • A. Marking for ingress traffic
  • B. Classification for ingress traffic
  • C. Rate limiting for egress traffic
  • D. Queuing for egress traffic

Answer: B


NEW QUESTION # 30
In which two ways can you assign a FortiSwitch port to a VDOM using multi-tenancy setup? (Choose two.)

  • A. Assign a port to a VDOM directly on the managed FortiSwitch.
  • B. Remove the managed FortiSwitch and allocate ports directly on FortiSwitch.
  • C. Switch the FortiLink interface to the target VDOM.
  • D. Create a virtual port pool on the FortiGate CLI.

Answer: A,D


NEW QUESTION # 31
Which two statements about managing a FortiSwitch stack on FortiGate are true? (Choose two.)

  • A. A FortiLink interface must be enabled on FortiGate.
  • B. Only a hardware-based FortiGate can manage a FortiSwitch stack.
  • C. The switch controller feature must be enabled on FortiGate.
  • D. FortiSwitch must be operating in standalone mode before authorization.

Answer: A,C


NEW QUESTION # 32
Which two types of Layer 3 interfaces can participate in dynamic routing on FortiSwitch? (Choose two.)

  • A. Switch virtual interfaces
  • B. Physical interfaces
  • C. Detected management interfaces
  • D. Loopback interfaces

Answer: A,D


NEW QUESTION # 33
Refer to the exhibit.

The exhibit shows the current status of the ports on the managed FortiSwitch. Access-1.
Why would FortiGate display a serial number in the Native VLAN column associated with the port23 entry?

  • A. port23 is a member of a trunk that uses the Access-1 FortiSwitch serial number as the name of the trunk.
  • B. port23 is configured as the dedicated management interface.
  • C. A standalone switch with the shown serial number is connected on port23.
  • D. Ports connected to adjacent FortiSwitch devices show their serial number as the native VLAN.

Answer: C


NEW QUESTION # 34
Exhibit.

port1 and port2 are the only ports configured with the same native VLAN 10.
What are two reasons that can trigger port1 to shut down? (Choose two.)

  • A. An endpoint sent BPDU on port1 it received from another interface.
  • B. Oport1 was shut down by loop guard protection.
  • C. Loop guard frame sourced from port 1 was received VLAN 10 ports.
  • D. STP triggered a loop and applied loop guard protection on port1.

Answer: B,C


NEW QUESTION # 35
......


To prepare for the Fortinet NSE6_FSW-7.2 Certification Exam, candidates must have a strong understanding of networking concepts, such as routing, switching, and VLANs. They should also have experience working with Fortinet’s FortiGate firewall products, as the FortiSwitch integrates closely with these devices. Candidates will need to demonstrate their ability to configure and manage the FortiSwitch using the FortiSwitch web-based management interface, as well as the FortiGate GUI. Upon passing the exam, candidates will earn their Fortinet NSE 6 - FortiSwitch 7.2 certification, which validates their ability to deploy and manage FortiSwitch products in enterprise environments.

 

DumpsActual NSE6_FSW-7.2 Exam Practice Test Questions: https://examtorrent.dumpsactual.com/NSE6_FSW-7.2-actualtests-dumps.html